Daily Plan: 2026-04-08

02:59 PM Plan (gemini-20260408-1458)

Hypothesis: Aggressive misting for dry afternoons (RH < 20%) combined with explicit zero-bug prevention for critical parameters will maximize time-in-band while relying on gas heating for cold nights.

Experiment: Explicitly setting temp_high, temp_low, and vpd_high in the immediate waypoint to prevent the dispatcher zero-bug while deploying aggressive 30s mister gaps for the 12% RH afternoon.

Journal: Expect aggressive misting to suppress VPD spikes during the 12% RH afternoon on Apr 9. Managing the risk of dispatcher zero-bugs by explicitly declaring critical boundaries. Next time, evaluate if 30s mister gaps cause any pooling or if they perfectly offset the extreme dry air.

Waypoints (19)

TimeParameterValueReason
2026-04-08T15:00:00-06:00temp_high78explicitly set to prevent zero bug and establish cooling ceiling
2026-04-08T15:00:00-06:00temp_low62explicitly set to prevent zero bug and establish heating floor
2026-04-08T15:00:00-06:00vpd_high1.2explicitly set to prevent zero bug and maintain VPD accounting
2026-04-08T15:00:00-06:00mister_engage_kpa1.3aggressive misting for current dry afternoon conditions
2026-04-08T15:00:00-06:00mister_pulse_gap_s30shorter gaps to fight low RH
2026-04-08T15:00:00-06:00mister_water_budget_gal500ensure misting is not blocked by zero budget safety rail
2026-04-08T15:00:00-06:00d_cool_stage_22aggressive cooling for warm afternoon
2026-04-08T20:00:00-06:00mister_engage_kpa1.6relax misting for night
2026-04-08T20:00:00-06:00mister_pulse_gap_s45standard gap for night
2026-04-08T20:00:00-06:00min_heat_on_s120prevent short cycling on cold night
2026-04-08T20:00:00-06:00min_heat_off_s120allow heat distribution
2026-04-09T12:00:00-06:00mister_engage_kpa1.3pre-position misting for 12% RH afternoon
2026-04-09T12:00:00-06:00mister_pulse_gap_s30aggressive humidity control
2026-04-09T12:00:00-06:00d_cool_stage_22early stage 2 cooling
2026-04-09T20:00:00-06:00mister_engage_kpa1.6relax misting for night
2026-04-09T20:00:00-06:00mister_pulse_gap_s45standard gap for night
2026-04-10T12:00:00-06:00mister_engage_kpa1.6standard misting for cooler, more humid day
2026-04-10T12:00:00-06:00mister_pulse_gap_s45standard gap
2026-04-10T12:00:00-06:00d_cool_stage_23standard cooling delta

06:23 PM Plan (gemini-20260409-0022)

Hypothesis: Aggressively pre-mist and pre-cool on April 9th to combat the forecasted 12% RH and 2.3 VPD, while relying on the gas heater’s efficiency during the 35-40F nights.

Experiment: Hold mister_pulse_gap_s at 30s through the peak of April 9th to test if tighter misting intervals can prevent the 6.5+ hours of VPD stress observed yesterday.

Journal: Yesterday saw 6.57 hours of VPD stress and 5.7 hours of heat stress. Today’s forecast is even drier (12% RH, 2.3 VPD). I expect the aggressive 1.3 kPa mister engagement and 30s pulse gaps to cap VPD stress, though temperature overshoot is structurally inevitable. If VPD stress remains high, I will increase mister_pulse_on_s next cycle.

Waypoints (15)

TimeParameterValueReason
2026-04-09T01:00:00+00:00temp_low64.0Explicitly set night temperature floor to prevent dispatcher zero-out bug
2026-04-09T01:00:00+00:00temp_high69.0Explicitly set night temperature ceiling
2026-04-09T01:00:00+00:00mister_water_budget_gal300.0Ensure sufficient water budget for the extremely dry day ahead
2026-04-09T01:00:00+00:00min_heat_on_s120.0Prevent short-cycling of the gas heater during 40F night
2026-04-09T13:00:00+00:00d_cool_stage_22.0Aggressive early cooling before the solar peak
2026-04-09T13:00:00+00:00mister_engage_kpa1.3Pre-mist early to build humidity before the 12% RH afternoon crash
2026-04-09T13:00:00+00:00mister_pulse_gap_s30.0Shorten gaps between misting pulses to prevent humidity collapse
2026-04-09T18:00:00+00:00temp_low72.0Explicitly set peak day temperature floor
2026-04-09T18:00:00+00:00temp_high78.0Explicitly set peak day temperature ceiling
2026-04-09T18:00:00+00:00vpd_high1.2Explicitly set peak day VPD ceiling
2026-04-09T18:00:00+00:00temp_hysteresis2.0Widen deadband during peak heat to save fan relays from chattering
2026-04-10T01:00:00+00:00mister_engage_kpa1.5Relax misting engagement for the milder, more humid day 2
2026-04-10T01:00:00+00:00mister_pulse_gap_s45.0Return to standard misting gaps
2026-04-10T01:00:00+00:00d_cool_stage_23.0Return to standard cooling staging
2026-04-10T18:00:00+00:00temp_high78.0Explicitly set temp_high to prevent dispatcher zero-out bug on day 2